Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 9.882µH
Inductance - Connected In Series 39.53µH
Tolerance ±20%
Current Rating - Parallel 2.41A
Current Rating - Series 1.2A
Current Saturation - Parallel 3.17A
Current Saturation - Series 1.58A
DC Resistance (DCR) - Parallel 48.9mOhm
DC Resistance (DCR) - Series 196mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.299" L x 0.299" W (7.60mm x 7.60mm)
Height 0.175" (4.45mm)
DRQ127-1R0-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 3.284µH Inductance - Connected in Series 821nH Inductance - Connected in Parallel 2.61mOhm DC Resistance (DCR) - Parallel 15.5A Nonstandard, DRQ
View
DRQ125-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 12.34µH Inductance - Connected in Series 3.084µH Inductance - Connected in Parallel 6.3mOhm DC Resistance (DCR) - Parallel 9.26A Nonstandard, DRQ
View
DRQ125-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 189.9µH Inductance - Connected in Series 47.47µH Inductance - Connected in Parallel 74mOhm DC Resistance (DCR) - Parallel 2.71A Nonstandard, DRQ
View
DRQ125-681-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 2.719mH Inductance - Connected in Series 679.8µH Inductance - Connected in Parallel 1.1Ohm DC Resistance (DCR) - Parallel 700mA Nonstandard, DRQ
View
DRQ127-8R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 35.44µH Inductance - Connected in Series 8.861µH Inductance - Connected in Parallel 15.7mOhm DC Resistance (DCR) - Parallel 6.32A Nonstandard, DRQ
View
DRQ127-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.02mH Inductance - Connected in Series 1.005mH Inductance - Connected in Parallel 1.66Ohm DC Resistance (DCR) - Parallel 610mA Nonstandard, DRQ
View
DRQ73-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 405.6µH Inductance - Connected in Series 101.4µH Inductance - Connected in Parallel 527mOhm DC Resistance (DCR) - Parallel 730mA Nonstandard, DRQ
View
DRQ127-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 56.36µH Inductance - Connected in Series 14.09µH Inductance - Connected in Parallel 24.7mOhm DC Resistance (DCR) - Parallel 5.03A Nonstandard, DRQ
View
DRQ127-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 135.7µH Inductance - Connected in Series 33.92µH Inductance - Connected in Parallel 60mOhm DC Resistance (DCR) - Parallel 3.23A Nonstandard, DRQ
View
DRQ127-221-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 886µH Inductance - Connected in Series 221.5µH Inductance - Connected in Parallel 376mOhm DC Resistance (DCR) - Parallel 1.29A Nonstandard, DRQ
View
DRQ73-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 60.04µH Inductance - Connected in Series 15.01µH Inductance - Connected in Parallel 84.4mOhm DC Resistance (DCR) - Parallel 1.83A Nonstandard, DRQ
View
DRQ127-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 19.36µH Inductance - Connected in Series 4.841µH Inductance - Connected in Parallel 9.17mOhm DC Resistance (DCR) - Parallel 8.25A Nonstandard, DRQ
View